SNMP Reference Guide
Table Of Contents
- Introduction
- Audience
- What’s New in this Release
- Introduction to the SNMP Reference Guide
- General Content
- Server Administrator Instrumentation MIB
- Server Administrator Remote Access MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Storage Management MIB
- Server Administrator Change Management MIB
- Dell RAC Out-of-Band MIB
- How This Guide Defines Technical Terms
- SNMP Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Reference Guide Content Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- Instrumentation MIB Version Group
- Systems Management Software Group
- Systems Management Software
- Systems Management Software Name
- Systems Management Software Version Number Name
- Systems Management Software Build Number
- Systems Management Software Description Name
- Systems Management Software Supported Protocol
- Systems Management Software Preferred Protocol
- Systems Management Software Update Level Name
- Systems Management Software URL Name
- Systems Management Software Language Name
- Systems Management Software Global Version Name
- Systems Management Software Feature Flags
- Systems Management Software SNMP Agent Feature Flags
- Systems Management Software Manufacturer Name
- Systems Management Software Variable Values
- Systems Management Software
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- User Security Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Remote Access Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- Dell RAC Out-of-Band Group
- Product Information
- Chassis Status
- DRsGlobalSystemStatus
- DRsGlobalCurrStatus
- DRsIOMCurrStatus
- DRsKVMCurrStatus
- DRsRedCurrStatus
- DRsPowerCurrStatus
- DRsFanCurrStatus
- DRsBladeCurrStatus
- DRsTempCurrStatus
- DRsCMCCurrStatus
- DRsGlobalPrevStatus
- DRsIOMPrevStatus
- DRsKVMPrevStatus
- DRsRedPrevStatus
- DRsPowerPrevStatus
- DRsFanPrevStatus
- DRsBladePrevStatus
- DRsTempPrevStatus
- DRsCMCPrevStatus
- DRsIOMChangeTime
- DRsKVMChangeTime
- DRsRedChangeTime
- DRsPowerChangeTime
- DRsFanChangeTime
- DRsBladeChangeTime
- DRsTempChangeTime
- DRsCMCChangeTime
- Chassis Power
- CMC Power Information
- CMC PSU Information
- Chassis Alerts
- Legacy Alerting
- Traps
- Trap Variables
- Understanding the Trap Description
- Understanding Trap Severity
- Instrumentation Traps
- Miscellaneous Traps
- Temperature Probe Traps
- Cooling Device Traps
- Voltage Probe Traps
- Amperage Probe Traps
- Chassis Intrusion Traps
- Redundancy Unit Traps
- Power Supply Traps
- Memory Device Traps
- Fan Enclosure Traps
- AC Power Cord Traps
- Hardware Log Traps
- Processor Device Status Traps
- Pluggable Device Traps
- Battery Traps
- RAC Traps
- BMC Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
- Glossary
- Index

20 Introduction
What's New in Device Group
Added the following value to DellProcessorDeviceFamily enumeration:
• deviceFamilyIsSixCoreAMDOpteron (238)
What's New in Chassis Information Group
Added the following values to DellHostControlCapabilities enumeration:
• manualRebootWithOSShutdownCapable(16)
• manualRebootWithoutOSShutdownCapable(32)
• manualPowerOffWithOSShutdownCapable(64)
• manualPowerOffWithoutOSShutdownCapable(128)
• manualPowerCycleWithOSShutdownCapable(256)
• manualPowerCycleWithoutOSShutdownCapable(512)
Introduction to the SNMP Reference Guide
This reference guide provides a formatted version of the Server Administrator
Instrumentation MIB (filename 10892.mib), the Server Administrator
Remote Access MIB (filename dcs3rmt.mib), the Server Administrator Field
Replaceable Unit MIB (filename dcs3fru.mib), the Server Administrator
Storage Management MIB (filename dcstorag.mib), the Server Administrator
Change Management MIB (filename dellcm.mib) and the Dell RAC Out-of-
Band MIB (filename dellRAC.mib) that are released with the current version of
Dell™ OpenManage™ Server Administrator.
Sections in this guide follow MIB groups and provide explanations and
definitions for the terms used to define MIB objects. Content in this reference
guide is organized as documented in the following subsections.
General Content
Table 1-1 describes the sections that provide general information about the
MIBs documented in this guide.