Messages Reference Guide

98 Storage Management Message Reference
2081 Virtual disk
reconfigurati
on failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk has failed or is
corrupt. A user may also
have cancelled
the reconfiguration.
Action: Replace the
failed or corrupt disk.
You can identify a disk
that has failed by
locating the disk that
has a red “X” for its
status.
If the physical disk is
part of a redundant
array, then rebuild the
physical disk. When
finished, restart
the reconfiguration.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2081
1204
2082 Virtual disk
rebuild failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk has failed or is
corrupt. A user may also
have cancelled
the rebuild.
Action: Replace the
failed or corrupt disk.
You can identify a disk
that has failed by
locating the disk that
has a red “X” for its
status. Restart the
virtual disk rebuild.
Clear Alert
Number:
None.
Related Alert
Number: 2048
LRA Number:
2081
1204
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers