Messages Reference Guide
Storage Management Message Reference 95
2070 Virtual disk
initialization
cancelled
OK / Normal /
Informational
Cause: The virtual disk
initialization cancelled
because a physical disk
included in the virtual
disk has failed or
because a user cancelled
the virtual disk
initialization.
Action: If a physical
disk failed, then replace
the physical disk. You
can identify which disk
has failed by locating
the disk that has a
red “X” for its status.
Perform a rescan after
replacing the disk.
Restart the format
physical disk operation.
Restart the virtual disk
initialization.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
2074 Physical disk
rebuild
cancelled
OK / Normal /
Informational
Cause: The user has
cancelled the rebuild
operation.
Action: Restart the
rebuild operation.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers