Messages Reference Guide
Storage Management Message Reference 87
2050 Physical disk
offline
Warning /
Non-critical
Cause: A physical disk
in the disk group is
offline. The user may
have manually put the
physical disk offline.
Action: Perform a
rescan. You can also
select the offline disk
and perform a Make
Online operation.
Clear Alert
Number:
2158.
Related Alert
Number:
2099, 2196
LRA Number:
2070
903
2051 Physical disk
degraded
Warning /
Non-critical
Cause: A physical disk
has reported an error
condition and may be
degraded. The physical
disk may have reported
the error condition in
response to
a consistency check or
other operation.
Action: Replace the
degraded physical disk.
You can identify which
disk is degraded by
locating the disk that
has a red "X" for its
status. Perform a rescan
after replacing the disk.
Clear Alert
Number:
None.
Related Alert
Number: 2070
LRA Number:
None.
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers