Messages Reference Guide

System Event Log Messages for IPMI Systems 63
<Entity Name> PS
Redundancy
sensor redundancy
degraded.
Information Power supply redundancy
is degraded if one of the
power supply sources is
removed or failed.
<Entity Name> PS
Redundancy
sensor redundancy lost.
Critical Power supply redundancy is lost
if only one power supply is
functional.
<Entity Name> PS
Redundancy
sensor redundancy
regained.
Information This event is generated if the
power supply has been
reconnected or replaced.
<Power Supply Sensor
Name>
predictive failure
was asserted
Critical This event is generated when the
power supply is about to fail.
<Power Supply Sensor
Name>
input lost was
asserted
Critical This event is generated when the
power supply is unplugged.
<
Power Supply Sensor
Name
> predictive failure
was deasserted
Information This event is generated when the
power supply has recovered from
an earlier predictive failure event.
<
Power Supply Sensor
Name
> input lost was
deasserted
Information This event is generated when the
power supply is plugged in.
Table 3-5. Power Supply Events (continued)
Event Message Severity Cause