Messages Reference Guide

38 Event Message Reference
Power Supply Messages
Power supply sensors monitor how well a power supply is functioning. Power
supply messages listed in Table 2-8 provide status and warning information
for power supplies present in a particular chassis.
1305 Redundancy degraded
Redundancy unit:
<Redundancy location
in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state
was:
<State>
Warning A redundancy sensor in
the specified system
detected that one of the
components of the
redundancy unit has
failed but the unit is
still redundant.
The redundancy unit
location, chassis location,
previous redundancy
state, and the number of
devices required for full
redundancy are provided.
1306 Redundancy lost
Redundancy unit:
<Redundancy location
in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state
was:
<State>
Error A redundancy sensor in
the specified system
detected that one of the
components in the
redundant unit has been
disconnected, has failed,
or is not present.
The redundancy unit
location, chassis location,
previous redundancy
state, and the number of
devices required for full
redundancy are provided.
Table 2-7. Redundancy Unit Messages (continued)
Event
ID
Description Severity Cause