Messages Reference Guide

216 Storage Management Message Reference
2347 The rebuild
failed due to
errors on the
source
physical disk.
Critical /
Failure / Error
Cause: You are
attempting to rebuild
data that resides on a
defective disk.
Action: Replace the
source disk and restore
from backup.
Clear Alert
Number:
None.
Related Alert
Number:
2195, 2346
LRA Number:
2071
904
2348 The rebuild
failed due to
errors on the
target
physical disk.
Critical /
Failure / Error
Cause: You are
attempting to rebuild
data on a disk that is
defective.
Action: Replace the
target disk. If a rebuild
does not automatically
start after replacing the
disk, initiate the
Rebuild task. You may
need to assign the new
disk as a hot spare to
initiate the rebuild.
Clear Alert
Number:
None.
Related Alert
Number:
2195, 2346
LRA Number:
2071
904
2349 A bad disk
block could
not be
reassigned
during a
write
operation.
Critical /
Failure / Error
Cause: A write
operation could not
complete because the
disk contains bad disk
blocks that could not be
reassigned. Data loss
may have occurred and
data redundancy may
also be lost.
Action: Replace the
disk.
Clear Alert
Number:
None.
Related Alert
Number: 2346
LRA Number:
2071
904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP