Messages Reference Guide
Storage Management Message Reference 215
2343 The Check
Consistency
logging of
inconsistent
parity data is
disabled.
Warning /
Non-critical
Cause: The Check
Consistency can no
longer report errors in
the parity data.
Action: See the
hardware
documentation for
more information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2080
1203
2346 Error
occurred: %1
Warning /
Non-critical
Cause: A physical
device may have an
error. The %1 indicates
a substitution variable.
The text for this
substitution variable is
generated by the
firmware and is
displayed with the alert
in the Alert Log. This
text can vary depending
on the situation.
Action: Verify the
health of attached
devices. Review the
Alert Log for significant
events. Run the PHY
integrity diagnostic
tests. You may need to
replace faulty hardware.
Make sure the cables are
attached securely. See
the hardware
documentation for
more information.
Clear Alert
Number:
None.
Related Alert
Number:
2048, 2050,
2056, 2057,
2076, 2079,
2081, 2083,
2095, 2129,
2201, 2203,
2270, 2282,
2369
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers