Messages Reference Guide

Storage Management Message Reference 207
2329 SAS port
report: %1
Warning /
Non-critical
Cause: The text for this
alert is generated by the
controller and can vary
depending on the
situation. The %1
indicates a substitution
variable. The text for this
substitution variable is
generated by the
controller and is
displayed with the alert
in the Alert Log. This
text can vary depending
on the situation.
Action: Run the PHY
integrity test diagnostic.
Make sure the cables are
attached securely. If the
problem persists, replace
the cable with a valid
cable according to SAS
specifications. If the
problem still persists,
you may need to replace
some devices such as the
controller or EMM. See
the hardware
documentation for more
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2060
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers