Messages Reference Guide

206 Storage Management Message Reference
2327 The NVRAM
has
corrupted
data. The
controller is
reinitializing
the NVRAM.
Warning /
Non-critical
Cause: The nonvolatile
random access memory
(NVRAM) is corrupt.
This may occur after a
power surge, a battery
failure, or for other
reasons. The controller
is reinitializing the
NVRAM. The controller
properties will reset to
the default settings
after the reinitialization
is complete.
Action: None. The
controller is taking the
required corrective
action. If this alert is
generated often (such
as during each reboot),
replace the controller.
Clear Alert
Number:
None.
Related Alert
Number: 2266
LRA Number:
2060
753
2328 The NVRAM
has corrupt
data.
Warning /
Non-critical
Cause: The NVRAM
has corrupt data. The
controller is unable to
correct the situation.
Action: Replace the
controller.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2060
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers