Messages Reference Guide

Storage Management Message Reference 191
2300 The
enclosure is
unstable.
Critical /
Failure / Error
Cause: The controller is
not receiving a
consistent response
from the enclosure.
There could be
a firmware problem or
an invalid cabling
configuration. If the
cables are too long, they
will degrade the signal.
Action: Power down all
enclosures attached to
the system and reboot
the system. If the
problem persists,
upgrade the firmware to
the latest supported
version. You can
download the most
current version of the
driver and firmware
from support.dell.com.
Make sure the cable
configuration is valid.
See the hardware
documentation for valid
cabling configurations.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2091
854
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers