Messages Reference Guide

184 Storage Management Message Reference
2282 Hot spare
SMART
polling
failed.
Critical /
Failure / Error
Cause: The controller
firmware attempted a
SMART polling on the
hot spare but was
unable to complete it.
The controller has lost
communication with
the hot spare.
Action: Check the
health of the disk
assigned as a hot spare.
You may need to replace
the disk and reassign
the hot spare. Make
sure the cables are
attached securely. See
the Dell OpenManage
Server Administrator
Storage Management
User’s Guide for more
information on
checking the cables.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2071
904
2285 A disk media
error was
corrected
during
recovery.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP