Messages Reference Guide

168 Storage Management Message Reference
2245 A virtual disk
blink has
ceased.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
2246 The
controller
battery is
degraded.
Warning /
Non-critical
Cause: The controller
battery charge is weak.
Action: As the charge
weakens, the charger
should automatically
recharge the battery.
If the battery has
reached its recharge
limit, replace the
battery pack. Monitor
the battery to make sure
that it recharges
successfully. If the
battery does not
recharge, replace the
battery pack.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2100
1153
2247 The
controller
battery is
charging.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
2358.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP