Messages Reference Guide
Storage Management Message Reference 155
2200 Replace
operation is
not possible,
because the
physical disk
type or bus
protocol is
different
from the
virtual disk
type or bus
protocol.
Warn in g/
Noncritical
Cause: This alert is
provided for
informational purposes.
Replace member
operation cannot be
performed because the
target physical disk is of
a different type (SAS
HDD/SATA HDD/
SATA SSD) from the
rest of the virtual disk.
SAS HDD, SATA HDD,
and SATA SSD are not
supported on the same
virtual disk.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
903
2201 A global hot
spare failed.
Warning /
Non-critical
Cause: The controller is
not able to
communicate with a
disk that is assigned as a
dedicated hot spare.
The disk may have been
removed. There may
also be a bad or loose
cable.
Action: Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert
Number:
None.
Related Alert
Number: 2048
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers