Messages Reference Guide

148 Storage Management Message Reference
2183 Replace
member
operation
failed on
physical
disk %1
Critical /
Failure / Error
Cause: The physical
disk being replaced has
failed.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
2060.
LRA Number:
None
904
2184 Replace
member
operation
cancelled on
physical disk
OK / Normal /
Informational
Cause: User cancelled
the replace member
operation.
Action: None
Clear Alert
Number:
None
Related Alert
Number: 2060
LRA Number:
None
901
2185 Replace
member
operation
stopped for
rebuild of
hot spare on
physical disk
Warning/
Non-critical
Cause: This alert is
provided for
informational purposes
Action: None
Clear Alert
Number:
None
Related Alert
Number: 2060
LRA Number:
None
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers