Messages Reference Guide
146 Storage Management Message Reference
2178 The
controller
battery
Learn cycle
has
timed out.
Warning /
Non-critical
Cause: The controller
battery must be fully
charged before the
Learn cycle can begin.
The battery may be
unable to maintain a
full charge causing the
Learn cycle to timeout.
Additionally, the battery
must be able to
maintain cached data
for a specified period of
time in the event of a
power loss. For example,
some batteries maintain
cached data for
24 hours. If the battery
is unable to maintain
cached data for the
required period of time,
then the Learn cycle
will timeout.
Action: Replace the
battery pack as the
battery is unable to
maintain a full charge.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2100
1153
2179 The
controller
battery
Learn cycle
has been
postponed.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers