Messages Reference Guide
Storage Management Message Reference 143
2172 The
controller
battery
temperature
is normal.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2172 is a clear
alert for alert
2171.
Related Alert
Number:
None.
LRA Number:
None.
1151
2173 Unsupported
configuratio
n detected.
The SCSI
rate of the
enclosure
man-
agement
modules
(EMMs) is
not the
same.
EMM0 %1
EMM1 %2
Warning /
Non-critical
Cause: The EMMs in
the enclosure have a
different SCSI rate.
This is an unsupported
configuration. All
EMMs in the enclosure
should have the same
SCSI rate. The %
(percent sign) indicates
a substitution variable.
The text for this
substitution variable is
displayed with the alert
in the Alert Log and can
vary depending on the
situation.
Action: No action
required.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2090
853
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap