Messages Reference Guide

Storage Management Message Reference 141
2168 The
non-RAID
SCSI driver
version is
older than
the
minimum
required
level. See
readme.txt
for the
validated
driver
version.
Warning /
Non-critical
Cause: The version of
the driver does not
meet the minimum
requirements. Storage
Management may not
be able to display the
storage or perform
storage management
functions until you have
updated the system to
meet the minimum
requirements.
Action: See the Readme
file for the validated
driver version. Update
the system to meet the
minimum requirements
and then reinstall
Storage Management.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2050
103
2169 The
controller
battery needs
to be
replaced.
Critical /
Failure / Error
Cause: The controller
battery cannot recharge.
The battery may be old
or it may have been
already recharged the
maximum number of
times. In addition, the
battery charger may not
be working.
Action: Replace the
battery pack.
Clear Alert
Number:
None.
Related Alert
Number: 2118
LRA Number:
2101
1154
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP