Messages Reference Guide

Storage Management Message Reference 121
2123 Redundancy
lost
Warning /
Non-critical
Cause: A virtual disk or
an enclosure has lost
data redundancy. In the
case of a virtual disk,
one or more physical
disks included in the
virtual disk have failed.
Due to the failed
physical disk or disks,
the virtual disk is no
longer maintaining
redundant (mirrored or
parity) data. The failure
of an additional
physical disk will result
in lost data. In the case
of an enclosure, more
than one enclosure
component has failed.
For example, the
enclosure may have
suffered the loss of all
fans or all power
supplies.
Action: Identify and
replace the failed
components. To identify
the failed component,
select the Storage
object and click the
Health subtab.
Clear Alert
Number:
2124.
Related Alert
Number:
2048, 2049,
2057
LRA Number:
2080, 2090
1306
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap