Messages Reference Guide

Storage Management Message Reference 113
2110 SMART
warning
degraded
Warning /
Non-critical
Cause: A disk is
degraded and has
received a SMART alert
(predictive failure). The
disk is likely to fail in
the near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a non-
redundant virtual disk,
then back up the data
before replacing the
disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
2111 Failure
prediction
threshold
exceeded
due to test
Warning /
Non-critical
Cause: A disk has
received a SMART alert
(predictive failure) due
to test conditions.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers