2. Click Finish to complete the virtual disk reconfiguration. If you want to exit without changing the original virtual disk, click Exit Wizard.
Considerations for Concatenated to RAID 1 Reconfiguration on PERC 3/Si, 3/Di, and CERC SATA1.5/6ch
Controllers
When reconfiguring a concatenated virtual disk to a RAID 1 on a PERC 3/Si, 3/Di, or CERC SATA1.5/6ch controller, the reconfigured virtual disk may display the
Resynching state. When reconfiguring from a concatenated virtual disk to a RAID 1, data is copied from the single concatenated disk to the RAID 1 mirror. The
controller perceives this operation as similar to resynching a mirror, and therefore may display the Resynching state.
Performing a controller rescan during the virtual disk reconfiguration may also cause the virtual disk to display a Resynching state.
While the virtual disk displays a Resynching state, the "Pause Check Consistency" and "Cancel Check Consistency" tasks will be available. Executing either of
these tasks on the virtual disk while it is in Resynching state will cause the virtual disk to be in a Failed Redundancy state.
Format and Initialize; Slow and Fast Initialize
Does my controller support this feature? See "Supported Features."
The Format or Initialize task erases the files and removes the file systems on virtual disks while keeping the virtual disk configuration intact. Formatting or
initializing a virtual disk destroys all data on the virtual disk. If the boot partition resides on the virtual disk, it will be destroyed by the format operation.
Some controllers have BIOS settings for a fast initialize or a slow initialize. In this case, the Initialize task performs the type of initialization (fast or slow) that
is specified in the BIOS.
Other controllers have a Fast Initialize and Slow Initialize task available on the controller task drop-down menu. See "Considerations for Fast Initialize" and
"Considerations for Slow Initialize" for more information.
Considerations for Format
The format task applies to the PERC 3/Si, 3/Di, and CERC SATA1.5/6ch controllers. After the format is initiated, it cannot be cancelled.
Considerations for Initialize
The initialize task applies to the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers.
These controllers also have a Cancel Initialize and Background Initialization feature. For more information, see "Format and Initialize; Slow and Fast Initialize"
and "Background Initialization on PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, and 4e/Di Controllers."
Considerations for Fast Initialize
NOTE: On some controllers, performing a Rescan while a reconfiguration is in progress will cause the virtual disk configuration and the physical disk
state to display incorrectly. For example, changes to the virtual disk's RAID level may not be displayed and the state of physical disks that were added
to the virtual disk may display as Ready instead of Online.
NOTE: On a Linux system, you cannot format a virtual disk that contains a mounted volume.
NOTE: A fast initialization on the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers may occur so quickly
that the virtual disk's State does not display Initializing. Use the controller BIOS to change the initialization settings.