Users Guide
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2348
Description: The rebuild failed due to errors on the target physical disk.
Cause: You are attempting to rebuild data onto a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after replacing the disk, then initiate the Rebuild task. You may need to assign the new
disk as a hot spare in order to initiate the rebuild.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2349
Description: A bad disk block could not be reassigned during a write operation.
Cause: A write operation could not complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred on a
nonredundant virtual disk. Data redundancy may also be lost.
Action: Replace the disk.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2346
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2350
Description: There was an unrecoverable disk media error during the rebuild.