Users Guide

Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2080
SNMP Trap Number: 1203. See "SNMP Support for Storage Management Alerts" for more information.
2346
Description: Error occurred: %1
Cause: A physical device may have an error. The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and
is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: Verify the health of attached devices. Review the Alert Log for significant events. Run the PHY integrity diagnostic tests. You may need to replace faulty
hardware. Make sure the cables are attached securely. See "Cables Attached Correctly" for more information on checking the cables. See the hardware
documentation for more information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, 2129, 2201, 2203, 2270, 2282, 2369
Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2347
Description: The rebuild failed due to errors on the source physical disk.
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Restore your data from backup. Review the Alert Log to see if you have received alert "2095." If you contact technical support, you may be asked for
the media and sense key errors reported by alert "2095." See your system documentation for information about contacting technical support by using
telephone, fax, and Internet services.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Alert Number: 2071