Users Guide

Clear Alert Number: 2325. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2091
SNMP Trap Number: 1004. See "SNMP Support for Storage Management Alerts" for more information.
2325
Description: The power supply cable has been inserted.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2325 is a clear alert for alerts 2324 and 2312.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1001. See "SNMP Support for Storage Management Alerts" for more information.
2326
Description: A foreign configuration has been detected.
Cause: This alert is provided for informational purposes. The controller has physical disks that were moved from another controller. These physical disks
contain virtual disks that were created on the other controller. See "Foreign Configuration Operations" and "Clear Foreign Configuration" for more information.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.