Users Guide
Cause: The power supply unit is switched off. Either a user switched off the power supply unit or it is defective.
Action: Check to see whether the power switch is turned off or on. If it is turned off, turn it on. If the problem is not corrected, verify that the power cord is
attached and functional. If the problem is still not corrected or if the power switch is already turned on, then replace the power supply unit.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: 2323. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2091
SNMP Trap Number: 1004. See "SNMP Support for Storage Management Alerts" for more information.
2323
Description: The power supply is switched on.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1001. See "SNMP Support for Storage Management Alerts" for more information.
2324
Description: The AC power supply cable has been removed.
Cause: The power cable may be pulled out or removed.
Action: Reinsert the power cable.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.