Users Guide
Description: A power supply in the enclosure has an AC failure.
Cause: The power supply has an AC failure.
Action: Replace the power supply.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2325. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2122, 2324.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 1003. See "SNMP Support for Storage Management Alerts" for more information.
2313
Description: A power supply in the enclosure has a DC failure.
Cause: The power supply has a DC failure.
Action: Replace the power supply.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2323. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2122, 2322.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 1003. See "SNMP Support for Storage Management Alerts" for more information.
2314
Description: The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible.
Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware. You may need to reinstall Storage
Management or Server Administrator.