Users Guide
Clear Alert Number: None.
Related Alert Number: 2211
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 751. See "SNMP Support for Storage Management Alerts" for more information.
2305
Description: The physical disk is too small to be used for a rebuild.
Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that is being rebuilt. The new physical disk must
also use the same technology (for example, SAS or SATA) as the disk being rebuilt. If the rebuild does not start automatically after you have inserted a
suitable physical disk, then run the "Rebuild" task. See "Replacing a Failed Disk" for more information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2326
Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2306
Description: Bad block table is 80% full.
Cause: The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the table is full, bad disk
blocks can no longer be remapped which means that disk errors can no longer be corrected and data loss can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert. If necessary, restore from back up.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2307
Local Response Agent (LRA) Alert Number: 2070