Users Guide

Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2278
Description: The controller battery charge level is below a normal threshold.
Cause: The battery is discharging. A battery discharge is a normal activity during the battery Learn cycle. Before completing, the battery Learn cycle recharges
the battery. You should receive alert "2179" when the recharge occurs. For more information on the battery Learn cycle, see "Start Learn Cycle."
Action 1: Verify whether the battery Learn cycle is in progress. Alert "2176" indicates that the battery Learn cycle has initiated. The battery also displays the
Learn state while the Learn cycle is in progress.
Action 2: If a Learn cycle is not in progress, then replace the battery pack.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2199
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1151. See "SNMP Support for Storage Management Alerts" for more information.
2279
Description: The controller battery charge level is operating within normal limits.
Cause: This alert is provided for informational purposes. This alert indicates that the battery is recharging during the battery Learn cycle.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.