Users Guide
Description: Smart thermal shutdown is disabled.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 101. See "SNMP Support for Storage Management Alerts" for more information.
2264
Description: A device is missing.
Cause: The controller cannot communicate with a device. The device may be removed. There may also be a bad or loose cable.
Action: Verify that the device is present and not removed. If it is present, then check the cables. See "Cables Attached Correctly" for more information on
checking the cables. You should also check the connection to the controller battery and the battery health. A battery with a weak or depleted charge may
cause this alert.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2050, 2060, 2070, 2080, 2090, 2100
SNMP Trap Number: 753, 803, 853, 903, 953, 1003, 1053, 1103, 1153, 1203. See "SNMP Support for Storage Management Alerts" for more information.
2265
Description: A device is in an unknown state.
Cause: The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable. The system may
also be experiencing problems with the application programming interface (API). There could also be a problem with the driver or firmware.