Users Guide

(SAS HDD/SATA HDD/SATA SSD) from the rest of the virtual disk. SAS HDD, SATA HDD, and SATA SSD are not supported on the same virtual disk.
Action: None.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2201
Description: A global hot spare failed.
Cause: The controller is not able to communicate with a disk that is assigned as a global hot spare. The disk may have failed or been removed. There may also
be a bad or loose cable.
Action: Verify that the disk is healthy and that it has not been removed. Check the cables. See "Cables Attached Correctly" for more information on checking
the cables. If necessary, replace the disk and reassign the global hot spare.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2048
Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2202
Description: A global hot spare has been removed.
Cause: The controller is not able to communicate with a disk that is assigned as a global hot spare. The disk may have been removed. There may also be a
bad or loose cable.
Action: Verify that the disk is healthy and that it has not been removed. Check the cables. See "Cables Attached Correctly" for more information on checking
the cables. If necessary, replace the disk and reassign the global hot spare.