Users Guide
2182
Description: An invalid SAS configuration has been detected. Details: %1
Cause: The controller and attached enclosures are not cabled correctly. The %1 indicates a substitution variable. The text for this substitution variable is
displayed with the alert in the Alert Log and can vary depending on the situation.
Action: See the hardware documentation for information on correct cabling configurations.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2061
SNMP Trap Number: 754. See "SNMP Support for Storage Management Alerts" for more information.
2183
Description: Replace member operation failed on physical disk %1
Cause: The replaced physical disk has failed.
Action: None.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2060.
Local Response Agent (LRA) Alert Number: None
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2184
Description: Replace member operation cancelled on physical disk