Users Guide

SNMP Trap Number: 1151.See "SNMP Support for Storage Management Alerts" for more information.
2173
Description: Unsupported configuration detected. The SCSI rate of the enclosure management modules (EMMs) is not the same. EMM0 %1
EMM1 %2
Cause: The EMMs in the enclosure have a different SCSI rate. This is an unsupported configuration. All EMMs in the enclosure should have the same SCSI rate.
The % (percent sign) indicates a substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending
on the situation.
Action: Replace one or more EMMs so that all EMMs in the enclosure have the same SCSI rate.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 853
2174
Description: The controller battery has been removed.
Cause: The controller cannot communicate with the battery. The battery may be removed. The contact point between the controller and the battery may also
be degraded.
Action: Verify whether the battery is present. Replace the battery if it is not present. If the contact point between the battery and the controller is degraded,
you will need to replace either the battery or the controller or both. Refer to the hardware documentation for information on how to safely access, remove,
and replace the battery.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2188, 2318
Local Response Agent (LRA) Alert Number: 2100
SNMP Trap Number: 1153. See "SNMP Support for Storage Management Alerts" for more information.
2175