Users Guide

Description: The RAID controller firmware and driver validation was not performed. The configuration file is out of date or corrupted.
Cause: Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller firmware and drivers. This
situation has occurred because a configuration file is unreadable or missing data. The configuration file may be corrupted.
Action: Reinstall Storage Management.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2060
SNMP Trap Number: 753. See "SNMP Support for Storage Management Alerts" for more information.
2167
Description: The current kernel version and the non-RAID SCSI driver version are older than the minimum required levels. See readme.txt
for a list of validated kernel and driver versions.
Cause: The version of the kernel and the driver do not meet the minimum requirements. Storage Management may not be able to display the storage or
perform storage management functions until you have updated the system to meet the minimum requirements.
Action: See the Readme file for kernel and driver requirements. Update the system to meet the minimum requirements and then reinstall Storage
Management.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2050
SNMP Trap Number: 103. See "SNMP Support for Storage Management Alerts" for more information.
2168
Description: The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validated driver version.
Cause: The version of the driver does not meet the minimum requirements. Storage Management may not be able to display the storage or perform storage
management functions until you have updated the system to meet the minimum requirements.