For example, to delay the learn cycle for three days and 12 hours on controller 1, you would enter:
omconfig storage battery action=delaylearn controller=1 battery=0 days=3 hours=12
omconfig Connector Commands
The following sections provide the omconfig command syntax required to execute connector tasks.
Table 15-19. omconfig Connector Commands
omconfig Rescan Connector
Does my controller support this feature? See "Supported Features."
Use the following omconfig command to rescan a controller connector. This command rescans all connectors on the controller and is therefore similar to
performing a controller rescan.
Complete Syntax
omconfig storage connector action=rescan controller=id connector=id
where id is the controller ID and the connector ID as reported by the omreport command. To obtain these values, you would enter omreport storage controller
to display the controller IDs and then enter omreport storage connector controller=ID to display the IDs for the connectors attached to the controller.
Example Syntax
For example, to rescan connector 2 on controller 1, you would enter:
omconfig storage connector action=rescan controller=1 connector=2
omconfig Enclosure Commands
The following sections provide the omconfig command syntax required to execute enclosure tasks.
Table 15-20. omconfig Enclosure Commands
Required Command Levels (1, 2, 3)
Optional name=value Pairs
Documentation Section
omconfig storage connector
action=rescan controller=id connector=id
"omconfig Rescan Connector"
Required Command Levels
(1, 2, 3)
Optional name=value Pairs
Documentation Section
omconfig storage enclosure
action=enablealarm controller=id enclosure=<ENCLOSUREID>
"omconfig Enable Enclosure Alarm"
action=disablealarm controller=id enclosure=<ENCLOSUREID>
"omconfig Disable Enclosure Alarm"
action=setassettag controller=id enclosure=<ENCLOSUREID>
assettag=<string>
"omconfig Set Enclosure Asset Tag"
action=setassetname controller=id enclosure=<ENCLOSUREID>
assetname=<string>
"omconfig Set Enclosure Asset Name"
action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id
minwarn=n maxwarn=n
"omconfig Set Temperature Probe
Thresholds"
action=resettempprobes controller=id enclosure=<ENCLOSUREID> index=id
"omconfig Reset Temperature Probe
Thresholds"
action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n
maxwarn=n
"omconfig Set All Temperature Probe
Thresholds"
action=resetalltempprobes controller=id enclosure=<ENCLOSUREID>
"omconfig Reset All Temperature Probe
Thresholds"
action=blink controller=id enclosure=<ENCLOSUREID>
"omconfig Blink"