User's Manual

Use the following omconfig command syntax to set the Hot Spare Protection Policy for dedicated or global hot spares. See "Dedicated Hot Spare Protection
Policy" and "Global Hot Spare Protection Policy" for more information.
Complete Syntax
For dedicated hot spare protection policy, type:
omconfig storage globalinfo action=setprotectionpolicies type=dhs raid=<r1 | r5 | r6 | r10 | r50 | r60 | all> hscount=<0-16> warnlevel=<0-3>
where hscount is the number of hot spares to be assigned to the virtual disk
and warnlevel is the severity level you want to assign to the generated alert, if this policy is violated. Use hscount=0 warnlevel=0 to reset the dedicated hot
spare protection policy for the RAID level.
For global hot spare protection policy, type:
omconfig storage globalinfo action=setprotectionpolicies type=ghs hscount=<0-16> warnlevel=<0-3> includeghsinvdstate=<yes | no>
where hscount is the number of hot spares to be assigned to the virtual disk
and warnlevel is the severity level you want to assign to the generated alert, if this policy is violated. Use hscount=0 warnlevel=0 to reset the global hot
spare protection policy for the RAID level.
Example Syntax
To set the Dedicated Hot Spare Protection Policy for RAID 10 with severity level=warning if the threshold level of 2 hot spares is exceeded, enter the following:
omconfig storage globalinfo action=setprotectionpolicies type=dhs raid=r1 hscount=2 warnlevel=2
omconfig Controller Commands
The following sections provide the omconfig command syntax required to execute controller tasks.
Table 15-15.omconfigControllerCommands
Required
Command
Levels (1, 2,
3)
Optional name=value Pairs
Documentation
Section
omconfig
storage
controller
action=rescan controller=id
"omconfig Rescan
Controller"
action=enablealarm controller=id
"omconfig Enable
Controller Alarm"
action=disablealarm controller=id
"omconfig Disable
Controller Alarm"
action=quietalarm controller=id
"omconfig Quiet
Controller Alarm"
action=testalarm controller=id
"omconfig Test
Controller Alarm"
action=resetconfig controller=id [force=yes]
"omconfig Reset
Controller
Configuration"
action=createvdisk controller=id raid=<c| r0| r1| r5| r6 | r10| r50 | r60> size=<number | max | min>
pdisk=<PDISKID> [stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb| 128kb>] [cachepolicy=<d | c>]
[diskcachepolicy=<d | e>] [readpolicy=<ra| nra| ara| rc| nrc>] [writepolicy=<wb | wt | wc | nwc | fwb>]
[name=<string>] [spanlength=<n>]
NOTE: For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is an optional parameter
(default=2)
"omconfig Create
Virtual Disk"
action=setrebuildrate controller=id rate=<0 to 100>
"omconfig Set
Controller Rebuild
Rate"
action=setbgirate controller=id rate=<0 to 100>
"omconfig Set
Background
Initialization Rate"
action=setreconstructrate controller=id rate=<0 to 100>
"omconfig Set
Reconstruct Rate"
action=setcheckconsistency controller=id rate=<0 to 100>
"omconfig Set Check