User's Manual

2210
Description: Battery requires reconditioning. Initiate the battery learn cycle.
Cause: Battery requires reconditioning.
Action: Initiate the battery learn cycle.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None
SNMP Trap Number: 1153. See "SNMP Support for Storage Management Alerts" for more information.
2211
Description: The physical device is not supported.
Cause: The physical device is not supported. The physical device may not have a supported version of the firmware or the physical device may not be
supported by Dell.
Action: If the physical device is supported by Dell, then update the firmware to a supported version. If the physical device is not supported by Dell, then
replace the physical device with one that is supported.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2212
Description: The controller battery temperature is above normal.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1151
2213
Description: Recharge count maximum exceeded
Cause: The battery has been recharged more times than the battery recharge limit allows.
Action: Replace the battery pack.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.