User's Manual
Setting Alert Actions 77
Setting Alert Actions
BMC/iDRAC Platform Events Filter Alert
Messages
All possible Platform Event Filter (PEF) messages along with a description of
each event is listed in Table 8-1.
Table 8-1. PEF Alert Events
Event Description
Fan Probe Failure The fan is running too slow or not at all.
Voltage Probe Failure The voltage is too low for proper operation.
Discrete Voltage Probe
Failure
The voltage is too low for proper operation.
Temperature Probe
War ni ng
The temperature is approaching excessively high or low
limits.
Temperature Probe
Failure
The temperature is either too high or too low for proper
operation.
Chassis Intrusion
Detected
The system chassis has been opened.
Redundancy (PS or Fan)
Degraded
Redundancy for the fans and/or power supplies has been
reduced.
Redundancy (PS or Fan)
Lost
No redundancy remains for the system's fans and/or power
supplies.
Processor Warning A processor is running at less than peak performance or
speed.
Processor Failure A processor has failed.
PPS/VRM/DCtoDC
Warning
The power supply, voltage regulator module, or DC to DC
converter is pending a failure condition.
Power Supply/VRM/D2D
Failure
The power supply, voltage regulator module, or DC to DC
converter has failed.
book.book Page 77 Thursday, February 5, 2009 2:45 PM