Quick Reference Guide
Storage Management Message Reference 97
2082 Virtual disk
rebuild failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual disk
has failed or is corrupt.
A user may also have
cancelled the rebuild.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status. Restart the virtual
disk rebuild.
Clear Alert
Number:
None.
Related Alert
Number:
2048
2083 Physical disk
rebuild failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual disk
has failed or is corrupt.
A user may also have
cancelled the rebuild.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status. Rebuild the virtual
disk rebuild.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2085 Virtual disk
check
consistency
completed
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2085 is a clear
alert for alert
2058.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information