Quick Reference Guide

96 Storage Management Message Reference
2080 Physical disk
initialization
failed
Critical /
Failure / Error
Cause: The physical disk
has failed or is corrupt.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status. Restart the
initialization.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2081 Virtual disk
reconfig-
uration failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual disk
has failed or is corrupt.
A user may also have
cancelled
the reconfiguration.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for
its status.
If the physical disk is part
of a redundant array, then
rebuild the physical disk.
When finished, restart
the reconfiguration.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert