Quick Reference Guide
Storage Management Message Reference 89
2056 Virtual disk
failed
Critical /
Failure / Error
Cause: One or more
physical disks included in
the virtual disk have failed.
If the virtual disk is
non-redundant (does not
use mirrored or parity data),
then the failure of a single
physical disk can cause the
virtual disk to fail. If the
virtual disk is redundant,
then more physical disks
have failed than can be
rebuilt using mirrored or
parity information.
Action:
Create a new virtual
disk and restore from a
backup.
The disk controller, rebuild
the virtual disk by first
configuring a hot spare for
the disk, and then
initiating a write operation
to the disk. The write
operation will initiate a
rebuild of the disk.
Clear Alert
Number:
None.
Related Alert
Number:
2048, 2049,
2050, 2076,
2079, 2081,
2129, 2346
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information