Quick Reference Guide

Storage Management Message Reference 87
2050 Physical disk
offline
Warning /
Non-critical
Cause: A physical disk in
the disk group is offline.
The user may have
manually put the physical
disk offline.
Action: Perform a rescan.
You can also select the
offline disk and perform
a Make Online operation.
Clear Alert
Number:
2158.
Related Alert
Number:
2099, 2196
2051 Physical disk
degraded
Warning /
Non-critical
Cause: A physical disk has
reported an error condition
and may be degraded.
The physical disk may
have reported the error
condition in response to
a consistency check or
other operation.
Action: Replace the
degraded physical disk.
You can identify which disk
is degraded by locating the
disk that has a red "X" for
its status. Perform a rescan
after replacing the disk.
Clear Alert
Number:
None.
Related Alert
Number:
2070
2052 Physical disk
inserted
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
2065, 2305,
2367
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information