Quick Reference Guide
76 System Event Log Messages for IPMI Systems
POST Code Table
Table 3-13 lists the POST Code errors that are generated when a fatal error
occurs during system boot.
PCIE NonFatal Er: Non
Fatal IO Group
sensor, PCIe
error(<location>)
Warning This event is generated in association
with a CPU IERR.
I/O Fatal Err: Fatal
IO Group sensor,
fatal IO error
(<location>)
Critical This event is generated in association
with a CPU IERR and indicates the
PCI/PCIe device that caused the CPU
IERR.
Unknown system event
sensor unknown system
hardware failure was
asserted
Critical This event is generated when an
unknown hardware failure is detected.
Table 3-13. POST Code Errors
Fatal Error Code Description Cause
80 No memory detected This error code implies
that no memory is
installed.
81 Memory detected but is not
configurable
This error code
indicates memory
configuration error
that could be result of
bad memory,
mismatched memory
or bad socket.
82 Memory configured but not
usable.
This error code
indicates memory sub-
system failure.
Table 3-12. BIOS Generated System Events (continued)
Event Message Severity Cause