Quick Reference Guide

38 Event Message Reference
component fails but others are still operating. Redundancy is lost when the
number of components functioning falls below the redundancy threshold.
Table 2-7 lists the redundancy unit messages.
The number of devices required for full redundancy is provided as part of
the message, when applicable, for the redundancy unit and the platform.
For details on redundancy computation, see the respective platform
documentation.
Table 2-7. Redundancy Unit Messages
Event
ID
Description Severity Cause
1300 Redundancy sensor has
failed
Redundancy unit:
<Redundancy location
in chassis>
Chassis location:
<Name of chassis>
Previous redundancy
state was:
<State>
Warning A redundancy sensor in the
specified system failed.
The redundancy unit location,
chassis location, previous
redundancy state, and the
number of devices required
for full redundancy
are provided.
1301 Redundancy sensor
value unknown
Redundancy unit:
<Redundancy location
in chassis>
Chassis location:
<Name of chassis>
Previous redundancy
state was:
<State>
Warning A redundancy sensor in the
specified system could not
obtain a reading.
The redundancy unit location,
chassis location, previous
redundancy state, and the
number of devices required
for full redundancy
are provided.