Quick Reference Guide

194 Storage Management Message Reference
2357 SAS expander
error: %1
Critical /
Failure / Error
Cause: The %1 indicates a
substitution variable. The
text for this substitution
variable is generated by the
firmware and is displayed
with the alert in the Alert
Log. This text can vary
depending on the
situation.
Action: There may be a
problem with the
enclosure. Check the
health of the enclosure and
its components. by
selecting the enclosure
object in the tree view. The
Health subtab displays a
red "X" or yellow
exclamation point for
enclosure components that
are failed or degraded. See
the enclosure
documentation for more
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2358 The battery
charge cycle is
complete.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information