Quick Reference Guide

188 Storage Management Message Reference
2340 The BGI
completed
with
un-correctable
errors.
Critical /
Failure / Error
Cause: The BGI task
encountered errors that
cannot be corrected.
The virtual disk contains
physical disks that have
unusable disk space or disk
errors that cannot be
corrected.
Action: Replace the
physical disk that contains
the disk errors. Review
other alert messages to
identify the physical disk
that has errors. If the
virtual disk is redundant,
you can replace the
physical disk and continue
using the virtual disk. If the
virtual disk is
non-redundant, you may
need to recreate the virtual
disk after replacing the
physical disk. After
replacing the physical disk,
run Check Consistency to
check the data.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2341 The Check
Consistency
made
corrections
and
completed.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information