Quick Reference Guide
186 Storage Management Message Reference
2336 Controller
event log: %1
Critical /
Failure / Error
Cause: The %1 indicates a
substitution variable. The
text for this substitution
variable is generated by the
controller and is displayed
with the alert in the Alert
Log. This text is from
events in the controller
event log that were
generated while Storage
Management was not
running. This text can vary
depending on the
situation.
Action: See the hardware
documentation for more
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2337 The controller
is unable to
recover
cached data
from the
battery
backup
unit (BBU).
Critical /
Failure / Error
Cause: The controller was
unable to recover data from
the cache. This may occur
when the system is without
power for an extended
period of time when the
battery is discharged.
Action: Check if the
battery is charged and in
good health. When the
battery charge is
unacceptably low, it cannot
maintain cached data.
Check if the battery has
reached its recharge limit.
The battery may need to be
recharged or replaced.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information