Quick Reference Guide
Storage Management Message Reference 183
2330 SAS port
report: %1
OK / Normal /
Informational
Cause: The %1 indicates
a substitution variable.
The text for this
substitution variable is
generated by the controller
and is displayed with the
alert in the Alert Log.
This text can vary
depending on the
situation. This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2331 A bad disk
block has
been
reassigned.
OK / Normal /
Informational
Cause: The disk has a bad
block. Data has been
readdressed to another disk
block and no data loss has
occurred.
Action: Monitor the disk
for other alerts or
indications of poor health.
For example, you may
receive alert 2306. Replace
the disk if you suspect
there is a problem.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2332 A controller
hot plug has
been
detected.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information