Quick Reference Guide
Storage Management Message Reference 181
2326 A foreign
config-
uration has
been
detected.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
The controller has physical
disks that were moved from
another controller.
These physical disks
contain virtual disks that
were created on the other
controller. See the Import
Foreign Configuration and
Clear Foreign
Configuration section in the
Dell OpenManage Server
Administrator Storage
Management User’s Guide
for more information.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2327 The NVRAM
has corrupted
data. The
controller is
reinitializing
the NVRAM.
Warning /
Non-critical
Cause: The NVRAM has
corrupted data. This may
occur after a power surge, a
battery failure, or for other
reasons. The controller is
reinitializing the NVRAM.
Action: None. The
controller is taking the
required corrective action.
If this alert is generated
often (such as during each
reboot), replace the
controller.
Clear Alert
Number:
None.
Related Alert
Number:
2266
2328 The NVRAM
has corrupt
data.
Warning /
Non-critical
Cause: The NVRAM
has corrupt data. The
controller is unable to
correct the situation.
Action: Replace the
controller.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information