Quick Reference Guide

Storage Management Message Reference 179
2321 Single-bit
ECC error.
The DIMM is
critically
degraded.
There will be
no further
reporting.
Critical /
Failure / Error
Cause: The DIMM is
malfunctioning. Data loss
or data corruption is
imminent. The DIMM
must be replaced
immediately. No further
alerts will be generated.
Action: Replace the
DIMM immediately.
The DIMM is a part of the
controller battery pack.
See your hardware
documentation for
information on replacing
the DIMM.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2322 The DC
power supply
is switched
off.
Critical /
Failure / Error
Cause: The power supply
unit is switched off.
Either a user switched off
the power supply unit or it
is defective.
Action: Check if the power
switch is turned off. If it is
turned off, turn it on. If the
problem persists, check if
the power cord is attached
and functional. If the
problem is still not
corrected or if the power
switch is already turned on,
replace the power
supply unit.
Clear Alert
Number:
2323.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information