Quick Reference Guide

Storage Management Message Reference 175
2311 The firmware
on the EMMs
is not the
same version.
EMM0 %1
EMM1 %2
Warning /
Non-critical
Cause: The firmware on
the EMM modules is not
the same version. It is
required that both modules
have the same version of
the firmware. This alert
may be caused if you
attempt to insert an EMM
module that has a different
firmware version than an
existing module. The %1
and %2 indicate a
substitution variable.
The text for these
substitution variables is
displayed with the alert in
the Alert Log and can vary
depending on the
situation.
Action: Upgrade to the
same version of the
firmware on both
EMM modules.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2312 A power
supply in the
enclosure has
an AC failure.
Warning /
Non-critical
Cause: The power supply
has an AC failure.
Action: Replace the power
supply.
Clear Alert
Number:
2325.
Related Alert
Number:
2122, 2324.
2313 A power
supply in the
enclosure has
a DC failure.
Warning /
Non-critical
Cause: The power supply
has a DC failure.
Action: Replace the power
supply.
Clear Alert
Number:
2323.
Related Alert
Number:
2122, 2322.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information